Configuration

The security analysis reuse the dynaflow module and the dynaflow-default-parameters module.

Default parameters

The dynaflow-security-analysis-default-parameters module defines the default values for all specific parameters of a security analysis run with DynaFlow.

Optional parameters

contingenciesStartTime

contingenciesStartTime defines when the contingencies start, in seconds. If the start time occurs between two time steps the contingencies will start on the next time step. The default value of this property is 10.

Examples

YAML configuration:

dynaflow-security-analysis-default-parameters:
  contingenciesStartTime: 20

XML configuration:

<dynaflow-security-analysis-default-parameters>
  <contingenciesStartTime>20</contingenciesStartTime>
</dynaflow-security-analysis-default-parameters>