Configuration¶
The security analysis reuse the dynaflow module
and the dynaflow-default-parameters module.
Default parameters¶
The dynaflow-security-analysis-default-parameters module defines the default values for all specific parameters of a security analysis run with DynaFlow.
Optional parameters¶
contingenciesStartTime¶
contingenciesStartTime defines when the contingencies start, in seconds.
If the start time occurs between two time steps the contingencies will start on the next time step.
The default value of this property is 10.
Examples¶
YAML configuration:
dynaflow-security-analysis-default-parameters:
contingenciesStartTime: 20
XML configuration:
<dynaflow-security-analysis-default-parameters>
<contingenciesStartTime>20</contingenciesStartTime>
</dynaflow-security-analysis-default-parameters>