pypowsybl.network.Network.get_3_windings_transformers

Network.get_3_windings_transformers(all_attributes=False, attributes=None, **kwargs)[source]

Get a dataframe of 3 windings transformers.

Parameters:
  • all_attributes (bool) – flag for including all attributes in the dataframe, default is false

  • attributes (List[str] | None) – attributes to include in the dataframe. The 2 parameters are mutually exclusive. If no parameter is specified, the dataframe will include the default attributes.

  • kwargs (Buffer | _SupportsArray[dtype[Any]] | _NestedSequence[_SupportsArray[dtype[Any]]] | complex | bytes | str | _NestedSequence[complex | bytes | str]) – the data to be selected, as named arguments.

Returns:

A dataframe of 3 windings transformers.

Return type:

DataFrame

Notes

The resulting dataframe, depending on the parameters, will include the following columns:

  • rated_u0: the rated voltage of the transformer at middle point od the star model (in kV)

  • fictitious (optional): True if the transformer is part of the model and not of the actual network

  • r1: the leg 1 resistance of the transformer (in Ohm)

  • x1: the leg 1 reactance of the transformer (in Ohm)

  • b1: the leg 1 susceptance of transformer (in Siemens)

  • g1: the leg 1 conductance of transformer (in Siemens)

  • rated_u1: the leg 1 rated voltage of the transformer (in kV)

  • rated_s1: the leg 1 rated apparent power of the transformer (in MVA)

  • ratio_tap_position1: the leg 1 ratio tap changer current position

  • phase_tap_position1: the leg 1 phase tap changer current position

  • p1: the leg 1 active power flow on the transformer, NaN if no loadflow has been computed (in MW)

  • q1: the leg 1 reactive power flow on the transformer, NaN if no loadflow has been computed (in MVAr)

  • i1: the leg 1 current on the transformer, NaN if no loadflow has been computed (in A)

  • voltage_level1_id: the voltage level where the leg 1 of the transformer is connected

  • bus1_id: the bus where the leg 1 of the transformer is connected

  • bus_breaker_bus1_id (optional): the bus of the bus-breaker view where leg 1 of the transformer is connected

  • node1 (optional): the node where the leg 1 transformer is connected (only in node-breaker voltage levels)

  • connected1: True if the leg 1 of the transformer is connected to a bus

  • selected_limits_group_1 (optional): the name of the selected operational limits group selected for the leg 1 of the transformer

  • rho1 (optional): the leg 1 voltage ratio of the transformer at current tap position

  • alpha1 (optional): the leg 1 phase shift of the transformer at current tap position (in degree)

  • r1_at_current_tap (optional): the leg 1 resistance of the transformer at current tap position (in Ohm)

  • x1_at_current_tap (optional): the leg 1 reactance of the transformer at current tap position (in Ohm)

  • g1_at_current_tap (optional): the leg 1 susceptance of the transformer at current tap position (in Ohm)

  • b1_at_current_tap (optional): the leg 1 conductance of the transformer at current tap position (in Ohm)

  • r2: the leg 2 resistance of the transformer (in Ohm)

  • x2: the leg 2 reactance of the transformer (in Ohm)

  • b2: the leg 2 susceptance of transformer (in Siemens)

  • g2: the leg 2 conductance of transformer (in Siemens)

  • rated_u2: the leg 2 rated voltage of the transformer (in kV)

  • rated_s2: the leg 2 rated apparent power of the transformer (in MVA)

  • ratio_tap_position2: the leg 2 ratio tap changer current position

  • phase_tap_position2: the leg 2 phase tap changer current position

  • p2: the leg 2 active power flow on the transformer, NaN if no loadflow has been computed (in MW)

  • q2: the leg 2 reactive power flow on the transformer, NaN if no loadflow has been computed (in MVAr)

  • i2: the leg 2 current on the transformer, NaN if no loadflow has been computed (in A)

  • voltage_level2_id: the voltage level where the leg 2 of the transformer is connected

  • bus2_id: the bus where the leg 2 of the transformer is connected

  • bus_breaker_bus2_id (optional): the bus of the bus-breaker view where leg 2 of the transformer is connected

  • node2 (optional): the node where the leg 2 transformer is connected (only in node-breaker voltage levels)

  • connected2: True if the leg 2 of the transformer is connected to a bus

  • selected_limits_group_2 (optional): the name of the selected operational limits group selected for the leg 2 of the transformer

  • rho2 (optional): the leg 2 voltage ratio of the transformer at current tap position

  • alpha2 (optional): the leg 2 phase shift of the transformer at current tap position (in degree)

  • r2_at_current_tap (optional): the leg 2 resistance of the transformer at current tap position (in Ohm)

  • x2_at_current_tap (optional): the leg 2 reactance of the transformer at current tap position (in Ohm)

  • g2_at_current_tap (optional): the leg 2 susceptance of the transformer at current tap position (in Ohm)

  • b2_at_current_tap (optional): the leg 2 conductance of the transformer at current tap position (in Ohm)

  • r3: the leg 3 resistance of the transformer (in Ohm)

  • x3: the leg 3 reactance of the transformer (in Ohm)

  • b3: the leg 3 susceptance of transformer (in Siemens)

  • g3: the leg 3 conductance of transformer (in Siemens)

  • rated_u3: the leg 3 rated voltage of the transformer (in kV)

  • rated_s3: the leg 3 rated apparent power of the transformer (in MVA)

  • ratio_tap_position3: the leg 3 ratio tap changer current position

  • phase_tap_position3: the leg 3 phase tap changer current position

  • p3: the leg 3 active power flow on the transformer, NaN if no loadflow has been computed (in MW)

  • q3: the leg 3 reactive power flow on the transformer, NaN if no loadflow has been computed (in MVAr)

  • i3: the leg 3 current on the transformer, NaN if no loadflow has been computed (in A)

  • voltage_level3_id: the voltage level where the leg 3 of the transformer is connected

  • bus3_id: the bus where the leg 3 of the transformer is connected

  • bus_breaker_bus3_id (optional): the bus of the bus-breaker view where leg 3 of the transformer is connected

  • node3 (optional): the node where the leg 3 transformer is connected (only in node-breaker voltage levels)

  • connected3: True if the leg 3 of the transformer is connected to a bus

  • selected_limits_group_3 (optional): the name of the selected operational limits group selected for the leg 3 of the transformer

  • rho3 (optional): the leg 3 voltage ratio of the transformer at current tap position

  • alpha3 (optional): the leg 3 phase shift of the transformer at current tap position (in degree)

  • r3_at_current_tap (optional): the leg 3 resistance of the transformer at current tap position (in Ohm)

  • x3_at_current_tap (optional): the leg 3 reactance of the transformer at current tap position (in Ohm)

  • g3_at_current_tap (optional): the leg 3 susceptance of the transformer at current tap position (in Ohm)

  • b3_at_current_tap (optional): the leg 3 conductance of the transformer at current tap position (in Ohm)

This dataframe is indexed by the id of the three windings transformers